• <code id="bdr09"></code>
  • <del id="bdr09"><small id="bdr09"><samp id="bdr09"></samp></small></del>
    1. <big id="bdr09"><nobr id="bdr09"><track id="bdr09"></track></nobr></big>
    2. <pre id="bdr09"></pre>

    3. <th id="bdr09"><video id="bdr09"><acronym id="bdr09"></acronym></video></th>

        <big id="bdr09"><nobr id="bdr09"></nobr></big>
      1. <nav id="bdr09"></nav>
        Contact Us

        Contact Person : Ella

        Phone Number : 0755-81495850

        WhatsApp : +8613682556888

        Free call
        Contact Now

        400V 30/50kvar SVG Static Var Generator of Overall Efficiency More Than 97%

        Minimum Order Quantity : 1PCS Packaging Details : Standard Export Wooden Package
        Delivery Time : Within 15-30days after receiving your 30% TT deposit Payment Terms : L/C, T/T
        Supply Ability : 1000PCS/Month for Static Var Generator
        Place of Origin: China Brand Name: SOROTEC
        Certification: CE Model Number: Static Var Generator

        Detail Information

        Rated Input Line Voltage: 400/480/690V Compensation Capacity: 30/50/100kvar
        Input Phase Voltage Range: -20%~+15% Overall Efficiency: ≥97%
        Power Grid Frequency: 50Hz/60Hz (range:±10%) Parallel Operation: Unlimited
        Response Time: <10ms

        Product Description

        400V 30/50kvar SVG Static Var Generator of Overall Efficiency More Than 97%

        400V 30/50kvar SVG Static Var Generator of Overall Efficiency More Than 97%

         

        SVG Operating Principle:

        SVG checks the load current through the external CT, and performs computing through the external DSP to analyze the reactive content of the load current. After that, it controls the PWM signal generator based on the settings to send control signals to the internal IGBT. In this way,it generates reactive compensation current to implement dynamic reactive power compensation.

         

        400V 30/50kvar SVG Static Var Generator of Overall Efficiency More Than 97%

         

        400V 30/50kvar SVG Static Var Generator of Overall Efficiency More Than 97%

         

        Product Descriptions of Static Var Generator:

        System parameters
        Rated input line voltage 400/480/690V
        Input phase voltage range -20%~+15%
        Power grid frequency 50Hz/60Hz (range:±10%)
        Parallel operation Unlimited
        Overall efficiency ≥97%
        Power grid structure 3P3L/3P4L
        CT 150/5 ~ 10,000/5
        Performance indicators
        Compensation capacity 30/50/100kvar
        Response time <10ms
        Target power factor Adjustable from -1 to +1
        Cooling mode Smart air cooling: 220L/sec Smart air cooling: 405L/sec
        Noise level per module <65dB
        Communications and monitoring capabilities
        Communications ports RS485, CAN, and network port
        Communications protocols Modbus and PMBus
        Alarm Available
        Monitoring Monitoring module, and optional centralized monitoring modules
        Environment requirement
        Altitude 1500 m. Between 1500 m to 4000 m, according to GB/T3859.2, the power decreases by 1% for every additional 100 m.
        Operating temperature -10 ~ 40
        Relative humidity 5%~ 95%, non-condensing
        Protection class IP20 (other IP classes are customizable.) IP20
         

         

        SOROTEC All the Inverter Series :

         

        modified sine wave inverter with charge IG3110.jpg IG3112E.jpg Pure sine wave inverter with ISO transformer IG3115C.jpg
        Modified Sine Wave Inverter with charge Pure Sine Wave Inverter for Solar System Sine Wave Inverter with ISO transformer
        high frequency pure sine wave inverter IG3117C.jpg MPPT solar charge.jpg off grid solar inverter with MPPT controller SSP3117C.jpg
        High Frequency Inverter with charger and AC power SCC mppt solar charge controller REVO Series Hybrid solar inverter

         

         
        APPLICATION OF OUR PRODUCT

         

        1. Living house and home building.

        2. Office building, factory and warehouse.

        3. Shopping mall, stadium and so on.

        4. Power station, field operation and some huge engineer construction.

        5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip.

         

         

        COMPANY SHOW

         

        Introduction of Company

        Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.

        Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.

         

         

        WHY CHOOSE US ?

         

        1, QC Control

        The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.

        2, Best Partner

        We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.

         

         
        FAQ

         

        1. How to choose suitable inverter?

         

        If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.

         

        For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.

         

        Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power

        .......................................................................................................................................................................

         

        2. How do I choose the size of the inverter?

         

        Different types of load demand for power are different. You can view the load power values to determine the

        size of the power inverter.

         

        Notice:

         

        Resistive load: you can choose the same power as the load.

         

        Capacitive loads: according to the load, you can choose 2-5 times power.

         

        Inductive loads: according to the load, you can choose 4-7 times power.

        .......................................................................................................................................................................

        3. How connection between batteries and an power inverter?

         

        We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions

        .......................................................................................................................................................................

         

        4. How to calculate the load of working hours requires configuration of the battery size?

         

        We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:

        Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)

        .......................................................................................................................................................................

         

        You Might Be Into These
        Get in touch with us

        Enter Your Message

        sales@soroups.com
        +8613682556888
        手机赚钱棋牌游戏